Harrington-hoists-and-cranes Static/Dynamic Hoist Load Tester Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
17
3. SYSTEM OPERATES SLOWLY
• Oil viscosity too high, cold oil Allow oil to warm up before operating
machine.
• Low oil level Check reservoir and add oil as necessary.
• Air in system Check suction side for leaks. Repair.
• Badly worn pump, valves, cylinders, etc. Repair or replace as needed.
• Restriction in filters or lines Clean and/or replace elements or lines.
Improper adjustments Check orifices, relief valves, etc. Adjust
per manual.
• Oil leaks Tighten fittings. Replace seals or damaged
lines.
4. SYSTEM OPERATES TOO FAST
• Wrong size or incorrectly adjusted Replace or adjust as necessary.
restrictor
5. OVERHEATING OF OIL IN SYSTEM
• Oil passing through relief valve for Return control valve to neutral when not
excessive time in use.
• Incorrect oil, low oil, or dirty oil Use recommended oil. Fill reservoir, clean
oil, replace filter element.
• Excessive component internal leakage Repair or replace component as necessary.
• Restriction in filters or lines Clean and/or replace elements or lines.
Insufficient heat radiation Clean dirt and mud from reservoir and
components.
• Malfunctioning component Repair or replace.
6. FOAMING OF OIL
Incorrect, low or dirty oil Replace, clean or add oil as needed.
• Air leaks Check suction line and component seals for
suction leaks. Replace.
7. NOISY PUMP
Low oil level, incorrect oil, foamy oil Replace, clean or add oil as needed.
• Suction line plugged, inlet screen Clean or replace.
plugged
• Worn or damaged pump Repair or replace
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 33 34

Comentarios a estos manuales

Sin comentarios